          800?Tests?Automatic?Biochemistry?Analyzer

          2020-09-26

          Engine Performance

          The instrument typeAutomatic random choose discrete; Emergency priority detection

          testing speed800T/H,1400 T/H with ISE

          test methodEnd point method, two points, rate method and the immune turbidimetry/double wavelength/wavelength s

          ingle wavelength method of linear and nonlinear calibration

          Test project: conventional biochemical, specific protein, electrolytes, drugs, drug abuse, urine, cerebrospinal fluid, etc

          analysis item at the same time: 90 photometric method, three electrode method.

          Sample System

          Track the style in this frameOnce every eight samples, can be on 176 samples, sample in a row

          Sample plate: 27 samples, support bar code scanning (optional), independent refrigeration (4-12 ℃), to ensure quality control and calibration at any time for 24 hours a day

          Sample size: 1.5 mu - 35 mu, 0.1 mul

          Sample: needle with bubbles and plugging needle, liquid level detection and collision safety protection function, 

          has the function of internal high pressure flushing, 1.5 mu minimum sample weight, 1.5 l - 35 mu, 0.1 mu l l progressive

          Sample processing: automatic dilution, automatic measurement

          Emergency samples: random insertion

          Reagent System

          The reagent disk90 reagents,Double plate design,Direct load70ml、35ml、

          20mlBottom reagent bottle ,With a maximum of 4 reagent test function

          Reagent refrigerated4-12 ℃ 

          reagent has 24 hours continuous cold storage refrigeration function,Parr stick refrigeration

          Reagent Volume:15μl-300μl、0.5μlstep,

          When testing can be deducted automatically reagent blank

          probe:Two, with functions of automatic liquid level detection and collision safety protection, among them, 

          the lining with functions of high pressure flushing, automatic recording reagent insufficient margin, 

          or cleaning reagent needle tip function: fully automatic water inside and outside wall cleaning, t

          ake all reagent pollution rate < 0.08% position fixed support bar code scanning (optional)

          Reaction System

          reaction disc :160new reaction cups,6mmlight path,Hard plastic colorimetric cup,

          (uv)Penetrating well、Acid-resistant,resistant to corrosion

          The reaction liquid volume150μl -300μl

          reaction temperature:37℃,The temperature accuracy±0.1℃

          constant temperature system:Is a maintenance free water bath

          rabbling mechanism:Two separate mixing needle、Laser nano polishing、

          Automatic frequency conversion technology

          Reaction cup clean:Eight steps after the determination of samples, the instrument adopts advanced automatic cleaning, 

          high pressure vacuum suction fluid, warm water wash, cleaning effect is better

          Reaction cup 2 kinds of cleaning fluid:

          1 kind of acid, alkali, vacuum suction fluid, automatic dilution

          liquid waste disposal:High and low concentration waste classification processing,

          With high concentration waste liquid alarm

           

          Optical System

          Light the lamp:halogen tungsten lamp,lifetime2000h

          After the grating spectrometer,12 wavelengthes,340-800nm

          detector:photodiode array

          Spectroscopic methods:Cluster type point source of light、After holographic concave grating ordinary, spectroscopic technique

           

          Calibration and Quality Control

          Calibration :Nine calibration formula,linear(A single point, two points, and more、

          Logit-Log4p、Logit-Log5p、The sample curve、exponential function、polynomial、

          parabola

          calibrating period:Automatically set or set as needed

          Quality control rules:Westgard Quality control rules,

          Cum μ Lative sum check The cumulative and rules、

          Twin plot Three, support for multiple levels quality control Three, 

          support for multiple levels quality control

          Quality control methodsQuality control, quality control in the day, days of real-time quality control

          Operating System

          Computer operating system:windows 2000above,multilanguage operating system

          data processingLarge capacity storage analysis sample test results,display,Store and print the response curve

          Print Report:Edit and print the complete language report,Optional print content format,Editable ,Support network report printing

          system interfacenetwork port

          Work Environment

          power:AC(110-220) ±22V 、50HZ(60HZ)±1HZ

          overall power consumption:≤2000VA

          environment temperature;15℃-30℃

          The maximum relative temperature:85%

          Host Volume :1860(L)×880(W)×1200(H)

          Copyright 長春賽諾邁德有限公司 版權所有.